Airway Resistance & Networks

Air loses pressure as it flows through rough airways. Learn Atkinson's equation, friction factors, airway resistance (p = RQ²), shock losses, series and parallel combinations, natural splitting of airflow, regulators, and ventilation network analysis with software.

A ventilation system is a network of airways, each resisting flow. Fans must supply enough pressure to overcome the total resistance at the required flow. Understanding resistance lets engineers size airways, choose fans and balance flows.

An analogy

Airways are like electrical resistors and fans like batteries — but for air, pressure is proportional to flow squared, not flow.

Friction factor

k depends on wall roughness: ≈ 0.004 for smooth concrete-lined shafts, 0.008–0.012 for typical blasted rock drives, 0.015–0.02 for irregular or obstructed airways. Area has a huge effect (A³): slightly larger drives greatly cut pressure loss.

Series and parallel

Airways in series add resistances. In parallel, air splits so that pressure drop is equal in each branch; the combined resistance is lower than any branch. Doubling identical parallel airways cuts resistance to one quarter.

Regulation

Natural splitting sends most air down low-resistance paths. Regulators (adjustable openings) add resistance to branches that get too much air, ensuring each working place gets its share — at the cost of extra fan pressure.

Network analysis

Kirchhoff's laws for ventilation (Σ Q = 0 at junctions, Σ p = 0 around loops) are solved by Hardy Cross iteration in software such as Ventsim, VnetPC and VUMA, which also simulate heat, gases, fires and contaminant spread.

Formulas

Worked example: Atkinson pressure drop

Given: Drift 5 × 5 m (A 25, C 20), L 1000 m; k 0.012, Q 100 m³/s

Find: p and R.

Answer: 154 Pa, R = 0.0154

Worked example: Parallel split

Given: R₁ = 0.0154, R₂ = 0.030; Total 150 m³/s

Find: R_p, p and split.

Answer: 117 Pa; 87 / 63 m³/s split

Common mistakes

Applications

Key takeaways

Going further