Deflection

Deflection is how far a beam moves under load. Learn the elastic curve EI·y″ = M, standard formulas for cantilevers and simply supported beams, superposition, and serviceability limits.

A beam can be strong enough and still unusable: floors that bounce, shelves that sag, machine frames that lose accuracy. Deflection checks — often L/250 to L/360 for buildings, much tighter for machines — frequently decide the size of a beam.

Deflection depends on load, span (cubed or to the fourth power!), E and I.

An analogy

A diving board: a longer board droops much more under the same diver. Span is the most sensitive variable.

What controls deflection

Deflection grows with load and dramatically with span (L³ or L⁴), and shrinks with stiffness EI. Doubling the span of a uniformly loaded beam makes it sag 16 times more.

Standard cases and superposition

Handbook formulas cover common cases. Because behaviour is linear, deflections from several loads can simply be added (superposition) — e.g. a beam's self-weight UDL plus a point load.

Serviceability limits

Typical limits: floors L/360 (live load), roofs L/250, crane girders L/600–L/1000, precision machine beams a few micrometres. Vibration (natural frequency) of floors is related: f ≈ 18/√δ(mm) Hz.

Integration, moment-area and energy methods

Double integration of EIy″ = M with boundary conditions gives the full curve; Macaulay brackets handle point loads. Moment-area and Castigliano's theorem are quicker for single values; FEM handles varying sections and indeterminate supports.

Formulas

Worked example: Simply supported beam

Given: L = 4 m, P = 10 kN at centre; E = 200 GPa, I = 20 × 10⁶ mm⁴

Find: Maximum deflection and check L/360.

Answer: 3.33 mm ✓

Worked example: Cantilever

Given: L = 1.5 m, P = 2 kN at tip; Steel 50 × 100 mm (on edge)

Find: Tip deflection.

Answer: 2.7 mm

Common mistakes

Applications

Key takeaways

Going further