Thermal Resistance

Heat flow behaves like electric current: temperature difference is the 'voltage' and thermal resistance the 'resistor'. Learn series/parallel networks, U-values, composite walls, contact resistance, critical insulation radius and electronics junction-to-ambient budgets.

Real heat paths pass through several layers — air film, plaster, brick, insulation, air film — or chip, solder, spreader, paste, heat sink, air. Treating each as a thermal resistance and adding them like resistors makes complex problems simple.

This is how building U-values and electronics cooling budgets are calculated.

An analogy

Ohm's law for heat: ΔT = Q̇ × R, just like V = I × R. Resistances in series add; the biggest one controls the flow.

Series and parallel paths

Layers one after another are in series: R_total = R₁ + R₂ + …. Side-by-side paths (a stud and insulation in a wall) are in parallel: 1/R = 1/R₁ + 1/R₂. The largest series resistance dominates — improve that one first.

U-values in buildings

U = 1/(R_si + ΣL/k + R_se), with standard surface resistances (≈ 0.13 inside, 0.04 outside m²K/W). Modern codes demand wall U ≈ 0.15–0.3 W/m²K. Thermal bridges (steel, concrete edges) bypass insulation and must be detailed out.

Electronics thermal budget

Chip power flows junction → case → interface → heat sink → air. With a maximum junction temperature (e.g. 125 °C) and ambient, the allowed total resistance is (T_J − T_A)/P; subtract known resistances to get the heat-sink requirement θ_SA.

Critical radius and thermal networks

Adding insulation to a small cylinder increases surface area for convection; below r_c = k/h, more insulation increases heat loss (useful for electrical wires). Large thermal networks with capacitances (RC networks) model transient behaviour of batteries, motors and buildings.

Formulas

Worked example: Composite wall U-value

Given: Inside film 0.10, brick 0.2/0.7, insulation 0.05/0.04, outside film 0.04 (m²K/W); ΔT = 25 K, area 10 m²

Find: U and heat loss; compare without insulation.

Answer: 149 W vs 587 W — insulation cuts loss by 75 %

Worked example: Heat-sink requirement

Given: CPU 100 W, T_J,max = 90 °C, ambient 35 °C; θ_JC = 0.2 K/W, θ_CS (paste) = 0.1 K/W

Find: Maximum heat-sink resistance.

Answer: Heat sink ≤ 0.25 K/W (a large tower cooler or liquid cooler)