Choppers

Choppers are DC–DC converters that 'chop' a DC voltage with a fast switch and filter it. Learn buck, boost and buck-boost conversion ratios, inductor and capacitor sizing, continuous vs discontinuous conduction, and efficiency.

Switching a DC voltage on and off quickly and averaging it with an inductor and capacitor lets you step voltage down (buck), up (boost) or both (buck-boost) with 90–98 % efficiency — far better than a linear regulator burning the excess as heat.

Every phone, laptop, LED driver, solar charge controller and EV contains several choppers. In drive systems, a chopper also controls DC motors and braking resistors.

An analogy

A buck converter is like filling a bucket from a fire hose by opening and closing the tap quickly: the bucket's water level (average voltage) depends on what fraction of the time the tap is open (duty cycle).

Volt-second balance

In steady state the inductor's average voltage over a cycle must be zero, or its current would ramp forever. Equating the volt-seconds during on-time and off-time gives every conversion ratio directly — for a buck, (V_in − V_o)·D = V_o·(1 − D) → V_o = D·V_in.

Why switching beats linear

A linear regulator dropping 12 V to 3.3 V at 3 A wastes (12 − 3.3) × 3 = 26 W. A buck converter at 92 % efficiency wastes about 0.9 W for the same 9.9 W output.

Ripple, CCM and DCM

The inductor current is a triangle around the load current. Designers typically set ΔI_L ≈ 20–40 % of full-load current. If the load is small enough that the current reaches zero each cycle, the converter enters discontinuous conduction mode (DCM), where the conversion ratio then depends on the load.

Boost and buck-boost

A boost stores energy in L while the switch is on and releases it on top of the input when off, so V_o > V_in. Its input current is continuous (good for PFC and solar), but its output current is pulsed. Buck-boost variants (inverting, SEPIC, Ćuk, four-switch) cover inputs both above and below the output, as with a battery that discharges past the output voltage.

Control and synchronous rectification

Voltage-mode and current-mode (peak or average) control regulate the output; current mode adds inherent current limiting and easier compensation. Replacing the freewheeling diode with a MOSFET (synchronous buck) cuts loss at low voltages. The boost's right-half-plane zero limits its control bandwidth.

Formulas

Worked example: Buck inductor sizing

Given: V_in = 24 V, V_o = 5 V; I_o = 2 A, ripple 30 % (0.6 A); f_sw = 200 kHz

Find: Duty cycle and inductance.

Answer: D ≈ 0.21, L ≈ 33 µH

Worked example: Li-ion to 5 V boost

Given: V_in = 3.7 V; V_o = 5 V at 1 A; Ideal (lossless)

Find: Duty cycle and average input current.

Answer: D = 0.26, I_in ≈ 1.35 A

Common mistakes

Applications

Key takeaways

Going further