Conduction

Conduction is heat flow through a solid (or still fluid) by molecular contact. Learn Fourier's law, thermal conductivity, plane walls, cylinders (pipes and insulation), and transient heating.

Hold one end of a metal spoon in hot tea and the other end soon feels warm. Heat travels through the metal from hot to cold by conduction: faster-vibrating atoms and free electrons pass energy to their neighbours.

Conduction controls heat loss through walls and pipes, how quickly a hot part cools, and how well a heat sink spreads heat from a chip.

An analogy

A bucket chain of people passing buckets: each passes energy to the next. Good conductors (metals) have a fast, efficient chain; insulators (foam) have a slow, sluggish one.

Thermal conductivity

k measures how well a material conducts heat. Copper ≈ 400, aluminium ≈ 205, steel ≈ 50, stainless ≈ 16, glass ≈ 1, brick ≈ 0.7, water ≈ 0.6, wood ≈ 0.15, mineral wool ≈ 0.04, still air ≈ 0.026 W/m·K. Insulation works by trapping still air.

Steady conduction in walls and pipes

In a plane wall the temperature falls linearly; in a pipe wall it falls logarithmically with radius. Insulating pipes and walls cuts heat loss dramatically — but adding insulation to very small wires can increase loss (critical radius r_c = k/h).

Transient conduction

When temperatures change with time (quenching, cooking, start-up), thermal diffusivity α governs how fast. If Bi < 0.1 the body is almost uniform in temperature (lumped model): T − T∞ = (T₀ − T∞)e^(−t/τ) with τ = ρcV/(hA).

Multidimensional conduction and numerics

The heat equation ∂T/∂t = α∇²T + q̇/ρc is solved analytically for simple shapes (Heisler charts, Fourier series) and numerically (finite difference/element) for real parts. Contact resistance between surfaces, anisotropic k (composites) and temperature-dependent k matter in electronics and aerospace.

Formulas

Worked example: Heat loss through a wall

Given: Brick k = 0.7 W/m·K, 0.2 m thick; Area 10 m², ΔT = 20 K

Find: Heat flow.

Answer: 700 W

Worked example: Insulated pipe

Given: Pipe OD 50 mm, insulation to 150 mm OD; k = 0.04, inner surface 150 °C, outer 30 °C

Find: Loss per metre.

Answer: ≈ 27.5 W/m